2.0mm²
The lighter gauge for lighting loops, switch legs, and general outlet circuits. Pulls easily through conduit and terminates clean — the same Class A copper core as every Volkin wire.
- Type
- THHN / THWN
- Cross-section
- 2.0mm² · 7-strand
- Construction
- 14/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 150 m
- Standards
- PNS 35 · UL 83 · RoHS 2
3.5mm²
Our most common gauge — the workhorse of residential and light commercial circuits. Pulls cleanly, terminates reliably, and carries current with minimal voltage drop.
- Type
- THHN / THWN
- Cross-section
- 3.5mm² · 7-strand
- Construction
- 12/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 150 m
- Standards
- PNS 35 · UL 83 · RoHS 2
5.5mm²
Stepped up for larger branch circuits, sub-feeds, and dedicated equipment runs. More copper for lower voltage drop over distance, without losing flexibility on the pull.
- Type
- THHN / THWN
- Cross-section
- 5.5mm² · 7-strand
- Construction
- 10/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 150 m
- Standards
- PNS 35 · UL 83 · RoHS 2
8.0mm²
For higher-load circuits — sub-panels, larger appliances, and feeders. The same Class A construction, scaled for current and built to the same uncompromising standard.
- Type
- THHN / THWN
- Cross-section
- 8.0mm² · 7-strand
- Construction
- 8/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 100 m
- Standards
- PNS 35 · UL 83 · RoHS 2
Built to Spec
Every gauge,
every meter
Concentric stranding, tight tolerances, and a flame-retardant jacket — manufactured to one uncompromising standard from conductor to coil.
Construction
Three layers,
one standard
Every Volkin wire is built to the same uncompromising specification — from conductor to jacket.
Conductor
Pure soft-drawn virgin electrolytic copper. 100% IACS conductivity for minimal voltage drop and stable current flow.
PVC Insulation
Lead-free and RoHS 2 compliant. A flame-retardant formulation resists ignition and self-extinguishes when the flame source is removed.
Nylon Jacket
A tough outer layer providing resistance to heat, moisture, abrasion, and common industrial chemicals — protecting the conductor through pulling, installation, and decades of service.
Inquire
Need materials for
your next project?
Tell us your specs and get product recommendations, specifications, and pricing tailored to your requirements.