Inquire

Our Products

THHN / THWN

VOLKIN 2mm² box front VOLKIN 2mm² box with wire coil

2.0mm²

The lighter gauge for lighting loops, switch legs, and general outlet circuits. Pulls easily through conduit and terminates clean — the same Class A copper core as every Volkin wire.

Type
THHN / THWN
Cross-section
2.0mm² · 7-strand
Construction
14/7 stranded
Rated voltage
600 V
Temperature
90°C (Dry) / 75°C (Wet)
Roll length
150 m
Standards
PNS 35 · UL 83 · RoHS 2
VOLKIN 3.5mm² box front VOLKIN 3.5mm² box with wire coil

3.5mm²

Our most common gauge — the workhorse of residential and light commercial circuits. Pulls cleanly, terminates reliably, and carries current with minimal voltage drop.

Type
THHN / THWN
Cross-section
3.5mm² · 7-strand
Construction
12/7 stranded
Rated voltage
600 V
Temperature
90°C (Dry) / 75°C (Wet)
Roll length
150 m
Standards
PNS 35 · UL 83 · RoHS 2
VOLKIN 5.5mm² box front VOLKIN 5.5mm² box with wire coil

5.5mm²

Stepped up for larger branch circuits, sub-feeds, and dedicated equipment runs. More copper for lower voltage drop over distance, without losing flexibility on the pull.

Type
THHN / THWN
Cross-section
5.5mm² · 7-strand
Construction
10/7 stranded
Rated voltage
600 V
Temperature
90°C (Dry) / 75°C (Wet)
Roll length
150 m
Standards
PNS 35 · UL 83 · RoHS 2
VOLKIN 8mm² box front VOLKIN 8mm² box with wire coil

8.0mm²

For higher-load circuits — sub-panels, larger appliances, and feeders. The same Class A construction, scaled for current and built to the same uncompromising standard.

Type
THHN / THWN
Cross-section
8.0mm² · 7-strand
Construction
8/7 stranded
Rated voltage
600 V
Temperature
90°C (Dry) / 75°C (Wet)
Roll length
100 m
Standards
PNS 35 · UL 83 · RoHS 2

Built to Spec

Every gauge,
every meter

Concentric stranding, tight tolerances, and a flame-retardant jacket — manufactured to one uncompromising standard from conductor to coil.

Construction

Three layers,
one standard

Every Volkin wire is built to the same uncompromising specification — from conductor to jacket.

01

Conductor

Pure soft-drawn virgin electrolytic copper. 100% IACS conductivity for minimal voltage drop and stable current flow.

02

PVC Insulation

Lead-free and RoHS 2 compliant. A flame-retardant formulation resists ignition and self-extinguishes when the flame source is removed.

03

Nylon Jacket

A tough outer layer providing resistance to heat, moisture, abrasion, and common industrial chemicals — protecting the conductor through pulling, installation, and decades of service.

Inquire

Need materials for
your next project?

Tell us your specs and get product recommendations, specifications, and pricing tailored to your requirements.