2.0mm²
The lighter gauge for lighting loops, switch legs, and general outlet circuits. Pulls easily through conduit and terminates clean — the same Class A copper core as every Volkin wire.
- Type
- THHN / THWN
- Cross-section
- 2.0mm² · 7-strand
- Construction
- 14/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 150 m
- Standards
- PNS 49 · UL 83 · RoHS 2
3.5mm²
Our most common gauge — the workhorse of residential and light commercial circuits. Pulls cleanly, terminates reliably, and carries current with minimal voltage drop.
- Type
- THHN / THWN
- Cross-section
- 3.5mm² · 7-strand
- Construction
- 12/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 150 m
- Standards
- PNS 49 · UL 83 · RoHS 2
5.5mm²
Stepped up for larger branch circuits, sub-feeds, and dedicated equipment runs. More copper for lower voltage drop over distance, without losing flexibility on the pull.
- Type
- THHN / THWN
- Cross-section
- 5.5mm² · 7-strand
- Construction
- 10/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 150 m
- Standards
- PNS 49 · UL 83 · RoHS 2
8.0mm²
For higher-load circuits — sub-panels, larger appliances, and feeders. The same Class A construction, scaled for current and built to the same uncompromising standard.
- Type
- THHN / THWN
- Cross-section
- 8.0mm² · 7-strand
- Construction
- 8/7 stranded
- Rated voltage
- 600 V
- Temperature
- 90°C (Dry) / 75°C (Wet)
- Roll length
- 100 m
- Standards
- PNS 49 · UL 83 · RoHS 2
Built to Spec
Every gauge,
every meter
Concentric stranding, tight tolerances, and a flame-retardant jacket — manufactured to one uncompromising standard from conductor to coil.
Construction
Three layers,
one standard
Every Volkin wire is built to the same uncompromising specification — from conductor to jacket.
Conductor
Pure soft-drawn virgin electrolytic copper. 100% IACS conductivity for minimal voltage drop and stable current flow.
PVC Insulation
Lead-free and RoHS 2 compliant. A flame-retardant formulation resists ignition and self-extinguishes when the flame source is removed.
Nylon Jacket
A tough outer layer providing resistance to heat, moisture, abrasion, and common industrial chemicals — protecting the conductor through pulling, installation, and decades of service.
Engineered for
performance
- PNS 49
- Philippine National Standard — thermoplastic insulated wires and cables
- UL 83
- Underwriters Laboratories — thermoplastic-insulated building wire
- RoHS 2
- Restriction of Hazardous Substances — lead-free formulation throughout
- Flame Retardancy
- Self-extinguishing on flame removal
- Conductor
- 100% IACS pure virgin electrolytic copper
Inquire
Need materials for
your next project?
Tell us your specs and get product recommendations, specifications, and pricing tailored to your requirements.